The CA-2500 2D Color Analyzer is an innovative, fourth generation, 2D Color Analyzer from Konica Minolta. It is also the successor to the CA-2000 2D Color Analyzer. The CA-2500 is an ideal instrument for evaluating luminance and chromaticity mura (non-uniformity) of a variety of display devices, such as LCD and OLED displays, and other light emitting devices such as automobile instrument panels and illuminated keypads. Unlike conventional imaging colorimeters that use RGB color separation filters, the CA-2500 uses XYZ filters that closely match the CIE 1931 color matching functions. This provides luminance and chromaticity measurements that correlate well with human eye sensitivity.
The CA-2500 2D Color Analyzer now comes with an improved minimum measurable luminance range (0.05 cd/m²) and is more durable, with service life measurement cycles of approximately 5 times that of the predecessor model. Furthermore, the new Data Management Software CA-S25w (included as a standard accessory of CA-2500) provides simple measurements. This is made possible by the introduction of the focus assist function, positioning assist function, and the automatic measurement area extraction function in the software. The software is also capable of measuring multiple samples simultaneously and provides evaluation results for each individual sample, resulting in greater measurement efficiency.
CA-2500 2D Color Analyzer
- XYZ filters provide high correlation with the spectral response of the human eye – uses XYZ filters that closely match the CIE 1931 color-matching functions to provide luminance and chromaticity measurements.
- Expanded low-luminance measurement range – minimum measureable luminance has been Improved from 0.1 cd/m² to 0.05 cd/m².
- Improved durability – service life measurement cycles have been increased to approximately 5 times that of the CA-2000
- Interchangeable lenses for measurements of various subjects are available.
- Advanced Data Management Software CA-S25w, as a standard accessory – focus assist function, positioning assist function, and automatic measurement area extraction function greatly simplify troublesome measurement preparations.
- SDK (software Development Kit), as a stand accessory, used by customer to efficiently create their own software for controlling the CA-2500.
- Capable of simultaneous measuring of multiple samples.
Specifications
Principal Specifications CA-2500
Lens | Standard lens | Wide lens | Telephoto lens* | |
Light receptor | 2/3-inch CCD image sensor (monochrome); Effective number of pixels: 1000×1000 (Measurement points: 980×980); Equipped with XYZ filter (closely matches CIE 1931 color-matching functions) and ND filter |
|||
Typical measurement sizes/distances (Approx. length per side of square/distance) |
98 mm/250 mm |
145 mm/200 mm |
115 mm/900 mm |
|
210 mm/500 mm |
410 mm/500 mm |
275 mm/2000 mm |
||
440 mm/1000 mm |
850 mm/1000 mm |
420 mm/3000 mm |
||
890 mm/2000 mm |
1770 mm/2000 mm |
With low-magnification macro ring: 57 mm/500 mm |
||
With high-magnification macro ring: 27 mm/300 mm |
||||
Measurement luminance range (including when ND filter is used) |
0.05 to 100,000 cd/m² |
0.25 to 100,000 cd/m²(0.5 to 100,000 cd/m² when high-magnification macro ring is used) |
||
Size |
Body only |
160 (W)×164 (H)×192 (D) mm (Height including handle: 211 mm) |
||
With lens/lens hood attached |
223 (D) mm |
219 (D) mm |
224 (D) mm |
|
With low-magnification macro ring: 230 (D) mm |
||||
With high-magnification macro ring: 237 (D) mm |
||||
Weight |
Approx. 3.5 kg (when Standard lens and lens hood are attached) |
|||
Power source |
Included AC adapter: 100 to 240V AC, 50/60Hz |
* Low-magnification macro ring and high-magnification macro ring can be attached only to Telephoto lens.
* Specifications are subject to change without prior notice.
Specifications
Principal Specifications CA-2500
Lens | Standard lens | Wide lens | Telephoto lens* | |
Light receptor | 2/3-inch CCD image sensor (monochrome); Effective number of pixels: 1000×1000 (Measurement points: 980×980); Equipped with XYZ filter (closely matches CIE 1931 color-matching functions) and ND filter |
|||
Typical measurement sizes/distances (Approx. length per side of square/distance) |
98 mm/250 mm |
145 mm/200 mm |
115 mm/900 mm |
|
210 mm/500 mm |
410 mm/500 mm |
275 mm/2000 mm |
||
440 mm/1000 mm |
850 mm/1000 mm |
420 mm/3000 mm |
||
890 mm/2000 mm |
1770 mm/2000 mm |
With low-magnification macro ring: 57 mm/500 mm |
||
With high-magnification macro ring: 27 mm/300 mm |
||||
Measurement luminance range (including when ND filter is used) |
0.05 to 100,000 cd/m² |
0.25 to 100,000 cd/m²(0.5 to 100,000 cd/m² when high-magnification macro ring is used) |
||
Size |
Body only |
160 (W)×164 (H)×192 (D) mm (Height including handle: 211 mm) |
||
With lens/lens hood attached |
223 (D) mm |
219 (D) mm |
224 (D) mm |
|
With low-magnification macro ring: 230 (D) mm |
||||
With high-magnification macro ring: 237 (D) mm |
||||
Weight |
Approx. 3.5 kg (when Standard lens and lens hood are attached) |
|||
Power source |
Included AC adapter: 100 to 240V AC, 50/60Hz |
* Low-magnification macro ring and high-magnification macro ring can be attached only to Telephoto lens.
* Specifications are subject to change without prior notice.